Part I | Chapter 7 146 Supplementary A Structure Parameter Dose constraint Soft Hard PTV V34.4Gy (V95%) ³ 99.0% CTV V34.4Gy (V95%) ³ 99.0% Bladder D5cm3 V28Gy V32Gy < 37.0 Gy < 15.0% < 20.0% Femur D10cm3 < 30.0 Gy Rectum D1cm3 V28Gy V32Gy £ 38.0 Gy £ 15.0% £ 20.0% Sphincter (distal 3 cm of rectum) Dmean < 20.0 Gy Supplementary B Table S1 – Target volume dose prescription and dose constraints for 5 x 7.25 Gy treatment. Legend: PTV = Planning Target Volume. CTV = Clinical Target Volume. VXXGy = Volume (%) receiving XX Gy. DXXcm3 = Highest dose to XX cm3 of the volume of interest. Figure S1 – Sagittal MR image displaying the bladder wall (BW) contours used for calculation of Doseacc. For reference, the Clinical Target Volume (CTV) and rectum contours are shown.